Case Studies
Real World Scenarios
In order to illustrate effectively just how much a 5th Energy Proactive Energy Management System™ can impact the bottom line, several actual case studies are shown below. These studies (names omitted) cover a variety of commercial facilities and clearly highlight potential savings.
Real World Scenario 1
Modern Office Park (Large), Test Conducted
This facility is located in Bryanston, is less than 3 years old and was constructed with energy efficient lighting throughout the office areas. The office area is approximately 75,000 sq-m with 113,000 sq-m of underground carparks. During the evening the facility is empty barring a skeleton team of security staff and a handful of office staff working over-time.
Electrosense conducted a test on one floor of one building of this complex. Based on the data acquired during a complete lighting audit of this floor, a 5th Energy Proactive Energy Management System™ was designed. The system and the savings to be realized are shown below.
System Design Parameters
- Number of lighting units: 246 Number of lamps/bulbs: 519
- Number of sensors: 56 Number of watts of switchable lighting: 23,342
- Average watts per sensor: 410 Separate electric meters installed to measure lighting only: 2
Test Results
- Number of KWh per day without the sensors: 632 Average number of KWh per day with the sensors: 179
Full Facility Audit
Based on the results of this test, a complete audit of the facility was conducted and a 5th Energy Proactive Energy Management System™ was designed for the entire facility.
System Design Parameters
#Number of watts of switchable lighting: 1,256,661 #Number of sensors: 2,534
Projected Full Client Savings
Real World Scenario 2
Older Office Park (Large)
This facility located in Braamfontein, is approximately 25 years old and was constructed with energy inefficient lighting throughout the office areas. The office area is approximately 55,000 sq-m with 5,000 sq-m of underground carparks. In addition there are numerous individual through-the-wall airconditioners. During the evening the facility is empty barring a skeleton team of security staff and a handful of office staff working over-time.
Electrosense conducted a complete audit of all floors, all buildings of this complex and a 5th Energy Proactive Energy Management System™ was designed to control the lights and the individual air conditioners. The system and the savings to be realized are shown below.
System Design Parameters
Projected Full Client Savings
Real World Scenario 3
Office Building (Small)
This facility is located in Rosebank, is approximately 10 years old and was constructed with a mixture of energy efficient energy inefficient lighting throughout the office areas. The office area is approximately 4,000 sq-m with approximately 1,000 sp-m of underground carparks. During the evening the facility is empty barring a skeleton team of security staff and a handful of office staff working over-time.
Electrosense conducted a complete audit of all floors and an Electro Sense Proactive Energy Management System™ was designed to control the lights. The system and the savings to be realized are shown below.